You must be logged in to edit your profile.
Profile
Product Description
Basic (necessary) components of lock system include:
· Software —management system
· Computer — used to install lock management software, prepared by hotel
· Card — as key card or setting card
· Lock — installed onto the door
Optional components of lock system include:
· Data register — used to collect the unlocking records from the locks.
· Energy- saving switch — use the key card to turn on lighting
· Elevator controller — control the elevator access of the key card
Parameter
Applicable card: TEMIC® Contactless RF card or MIFARE ONE® Contactless RF card, 100, 000 times life.
Material: Stainless steel; Stainless steel with golden PVD finished; Brass; Alloy with chrome plated—- moisture proof, fire retardant.
Power supply: 4 standard AAA alkaline batteries.
Low voltage warning: When power’s voltage is less 4.5V, there will be warning when unlock. The lock can still be unlocked about 200 times before the batteries are replaced.
Static consumption: 3uA.
Dynamic consumption: 180mA.
Humidity: 20%-80%
Working temperature: -250C~550C
Open time: The lock will be locked again automatically 7 seconds after unlocking.
Reliability of card insertion: No accident for 10, 000 times of continuous card insertion.
Installation
1. Installation request: To be installed on the door, with the thickness between 38mm and 70mm, and if the door surface is decorated,
The distance between the decorative edge and the edge of the door must be over 110mm.
2. Handle orientation: Left hand push to open, right hand push to open; Left hand pull to open, right hand pull to open
3. Multiple options for mortise: ANSI mortise (5 latch mortise) / European mortise (3 latch mortise)
4. Weight: 3.0kgs / set
Quality
- 1. CE certificate
- 2. FCC certificate
- 3. RoHS certificate.
- 4. ISO 9001: 2000-certified management,
- 5. KingDee ERP system,
- 6.16-step QC regimen,
- 7. Advanced production equipment to make sure the good quality
Wireless system and stand-alone door lock:no wiring, adopts card to perform control function and unlocking function | Restrict Guest room function: can make Stop Card to stop the corresponding keycard from unlocking the lock.&n bsp; |
Keycards are limited by lock’s clock .Do not disturb function, | The guest can pass the public access and elevator with his keycard.Avoid waiter’s incautious disturb. |
Keycards are grouped into several levels : Master Card: can unlock all of the locks in thehotel without time’s limited,Building Card: Can unlock the locks belong to corresponding buildingFloor Card: Can unlock the locks belong to corresponding floors.Guest Card: open the rooms within the specifying period of time |
Adopt the Access desktop database,Support SQLdatabase multi computers to issue card at the same time .Energy- saving function: Guest Card into the energy- saving switch to turn on the lightingReport the loss of key card |
A new Guest Card automatically locks out the keycard of the previous guest. | The lock memorizes more than 200 recordsReport the loss of key card |
Complete information inquires function.Distinctmanagement responsibility, more securityAlarm for not closing well | Offers software interfaces (DLL)connect to other hotel management system.and gain the interface license of micros Fidelio/Opera(certificate No. KYU-5003-091). |
Some of Our Clients
You must be logged in to edit your profile.
You must be logged in to edit your profile.
- 1 with high strength ABS plastic shell ,durable in use
- 2 Use digital code technology and the function is steady and reliable
- 3 Show 3-digit number and also can show ABCDHLPU,easy to distinguish the service area.from 001-999,A01-U99.
- 4 It can work with 1000pcs 1-key or multi-kesy call buttons in max
- 5 It can show differetn service type.fixed, slow flash, flash
- 6 It can save 5 calling info in turn,and apply in basic service places.
- 7 Calling Alert: sounds or music
You must be logged in to edit your profile.
What are the components of the wireless calling system?
- 1. Wireless receiver, installed on the count
- 2. Call button, installed on each table
- 3. Signal repeater (optional), enhance the signal
How does the system works?
- 1. After your customer gets seated the waiter informs them that when they require service, all they need to do is press the button sitting on their table.
- 2. When the customer presses the call button on their table, their table number will appear on the reciever with ringing. Waiters then head over to the table to take the order of the customer promptly and quickly.
You must be logged in to edit your profile.
- Working voltage:DC5V 500MA
- Working current:<20mA
- Working Frequency:315MHz±75k
- Dimension:210*148*30MMworking band: 315
- Remote distance: 500m ( no obstructions )
- Operating Temperature: -30~+80°C
- Receive sensitivity: -108dbm
- Static Current: <430mA
- Communication: Wireless
- Show number: Display 1 number at the same time
- Max number: 99
You must be logged in to edit your profile.
You must be logged in to edit your profile.
The Specification of call button K-M :
- 1. water-proof Call Black
- 2.work with our receiver to combined the wireless calling system
- 3.Can be installed on each table,when the customer need help only press the button,the
- calling no will be shown on the screen,so everyone can easy to know who is calling.
Technical Parameter:
- Working voltage: DC12V
- Working current: ≤35mA
- Use Frequency: 315MHz±75k
- Transmitted Power: ≤20mW
- Transmitted Distance>300m in open area
You must be logged in to edit your profile.
- 3-level Automatic Reception with voice guidance
- DISA (Direct Inward System Access) with message
- Built-in Voice Message (BV)
- Caller ID display on SLT and APT
- Flexible SMS routing
- Intuitive customisation and maintenance
- UCD (Uniform Call Distribution) with message
- Doorphones, Door Openers, and Doorbells
- Automatic configuration for outside (CO) line type
- Centralised feature setting for T7710 (PBX mode)
- PC programming (USB/RS232C) and easy maintenance
- CO busy out
- Budget management
- Call charge calculation
You must be logged in to edit your profile.
Features:
- Transfer caller ID
- Intercom caller ID
- Auto-attendant (DISA:20s Three paragraphs)
- DISA can be upgraded to 60s or 90s (optional)
- External music input on holding
- Internal music on holding
- Power failure transfer
- Door Phone and door opener function (optional)
- 11 chord melody music selectable, auto select daily
- CO line transfer to CO line
- Outgoing message recording
- Memory protect while power off
- FAX detection function ( optional)
- External call forwarding, eg.: extension forward the calls to mobile phone or other specified fixed phone (optional)
- Three way conference
- 2 Wireless SIMs (2 GSM SIMs are available) (GSM 850/900/1800/1900Mhz)
- LCR ( least call routing
Basic Functions:
- Multiple communication line
- Normal transform power
- Power failure transfer
- External line caller ID
- Internal music on holding
- Remote programming
- Memory protect while power off
- Multiple dial-out mode
- Call duration control
- Call pickup
- Outgoing call transfer
- Call transfer
- Call forwarding
- Flexible coding (change ext.No.)
- Do not disturb
- Automatic Ext. reporting
- Flash time choice
- Ringing assignment
- Call restriction
- Three way conference
- Call all extensions
- Specific CO line dialing
- Ring identify
- CO line booking
- CO line reservation
- Operator setting
- CO line monitor
You must be logged in to edit your profile.
- 4-Wire operation
- Optical & thermal detection
- Built-in alarm relay
- Wide operating voltage
- Advanced electronic technology
- Proven detection performance
- UL EN approval
- DETECTOR CLASS: Photoelectronic and thermal
- SUPPLY WIRING: 4 – WIRE
- DESIGN STANDARD: EN 54-7 and UL 268
- APPROVAL: CE; EN and UL
- SUPPLY VOLTAGE: 24V DC
- HUMIDITY: 0% to 95% RH No Condensation
- SENSITIVITY: UL:2.3%FT; EN 54:0.15dB/m
- IP RATING: IP 43
- START-UP TIME: 10 Seconds
You must be logged in to edit your profile.
- 2-Wire operation
- Optical & thermal detection
- Wide operating voltage
- Advanced electronic technology
- Proven detection performance
- Designed to meet approvals worldwide (e.g. UL EN CE)
- Sensor base: optional installation and wiring mode
- EN UL approval
- >DETECTOR CLASS:Combined Smoke and Heat
- SUPPLY WIRING:2 – WIRE
- DESIGN STANDARD:EN 54-5/7 and UL 521&268
- APPROVAL: CE; EN and UL
- TEMPERATURE RANGE: -10℃ to +55℃
- HUMIDITY: 0% to 95% RH No Condensation
- SENSITIVITY: UL:2.3%FT; EN 54:0.15dB/m
- IP RATING: IP 43
- START-UP TIME: 10 Seconds
You must be logged in to edit your profile.
- Fast-respond to ultraviolet radiation emitted by almost all flames
- Artistic and professional housing design
- Wide operating voltage
- 4-wire operation
- Built-in alarm relay
- Advanced electronic technology
- Proven detection performance
- Designed to meet approval worldwide.
- HUMIDITY: 0% to 95% RH No Condensation
- UV SENSITIVITY: 185 to 260 nm
- RESPONSE TIME: 5Sec for 30mm flame @ 5 meters
- START-UP TIME: 10 Seconds
You must be logged in to edit your profile.
- Power requirement: 9V battery
- Static current: Less than 50uA
- Alarm concentration:
- concentration 30ppm: make alarm in 120 minutes
- concentration 50ppm: make alarm between 60 to 90minutes
- Concentration 100ppm: alarm between 10 to 40minutes
- concentration 300ppm: alarm within 3 minutes
- Alarm current: less than 50mA
- High brightness light emitting diode
- Standy: flash per 50s;
- Alarm: fast flash
- Loud high-volume buzzer output: 85dB within 3m
You must be logged in to edit your profile.
- 1. Natural gas: 10%~25%LEL
- 2. Liquid gas: 10%~25%LEL
- 3. Coal gasification: 2%~5%LEL
- 4. power consumption: ≤1.5W
- 5. Response Time: <30s
- 6. Alarm volume: >65db
- 7. Control output: AC220V 5A
- 8. Working Temperature: -10°C ~+50°C
- 9. atmospheric pressure: 86~106Kpa
You must be logged in to edit your profile.