- Power requirement: 9V battery
- Static current: Less than 50uA
- Alarm concentration:
- concentration 30ppm: make alarm in 120 minutes
- concentration 50ppm: make alarm between 60 to 90minutes
- Concentration 100ppm: alarm between 10 to 40minutes
- concentration 300ppm: alarm within 3 minutes
- Alarm current: less than 50mA
- High brightness light emitting diode
- Standy: flash per 50s;
- Alarm: fast flash
- Loud high-volume buzzer output: 85dB within 3m
Posts Tagged / Fire Safety
Gas leakage detector for fire alarm
- 1. Natural gas: 10%~25%LEL
- 2. Liquid gas: 10%~25%LEL
- 3. Coal gasification: 2%~5%LEL
- 4. power consumption: ≤1.5W
- 5. Response Time: <30s
- 6. Alarm volume: >65db
- 7. Control output: AC220V 5A
- 8. Working Temperature: -10°C ~+50°C
- 9. atmospheric pressure: 86~106Kpa
Fire alarm smoke detector
- The smoke detector with network function: It can link 39 smoke detectors together. When one of them detect fire smoke, all the others will make sound and flash at same time to warn all the people;
- Independent ceiling installation
- stable, high sensitity
- optical principle smoke detecting
- Alarm output: sound and flash
- Power requirement: DC9V battery
- Static Current: ≤10uA
- Alarm Current: ≤12mA
- Battery low voltage alarm: ≤6.8v
- Sound level: more than 85dB/m
- Sound Level: More than 85dB/m
- Temperature: -10°C ~+50°C
- Humidity: ≤95% RH
- Detecting Area: 60 square meter(Install lower than 6M)
- Size: Dia107mm x 44mm
Independent Smoke Detector
- Independent ceiling installation
- stable, high sensitity
- optical principle smoke detecting
- Alarm output: sound and flash
- Power requirement: DC9V battery
- Static Current: ≤10uA
- Alarm Current: ≤12mA
- Battery low voltage alarm: ≤6.8v
- Sound level: more than 85dB/m
- Temperature: -10°C ~+50°C
- Humidity: ≤95% RH
- Detecting Area: 60 square meter(Install lower than 6M)
- Size: Dia107mm x 44mm
Photoelectronic smoke detector
- Independent ceiling installation
- stable, high sensitity
- optical principle smoke detecting
- Alarm output: sound and flash
- Power requirement: DC9V battery
- Static Current: ≤10uA
- Alarm Current: ≤12mA
- Battery low voltage alarm: ≤6.8v
- Sound level: more than 85dB/m
- Sound Level: More than 85dB/m
- Temperature: -10°C ~+50°C
- Humidity: ≤95% RH
- Detecting Area: 60 square meter(Install lower than 6M)
- Size: Dia107mm x 41mm
Photoelectronic smoke detector
- Independent ceiling installation
- stable, high sensitity
- optical principle smoke detecting
- Alarm output: sound and flash
- Power requirement: DC9V battery
- Static Current: ≤10uA
- Alarm Current: ≤12mA
- Battery low voltage alarm: ≤6.8v
- Sound level: more than 85dB/m
- Sound Level: More than 85dB/m
- Temperature: -10°C ~+50°C
- Humidity: ≤95% RH
- Detecting Area: 60 square meter(Install lower than 6M)
- Size: Dia107mm x 34mm
Photoelectronic smoke detector
- Independent ceiling installation
- stable, high sensitity
- optical principle smoke detecting
- Alarm output: sound and flash
- Power requirement: DC9V battery
- Static Current: ≤10uA
- Alarm Current: ≤12mA
- Battery low voltage alarm: ≤6.8v
- Sound level: more than 85dB/m
- Sound Level: More than 85dB/m
- Temperature: -10°C ~+50°C
- Humidity: ≤95% RH
- Detecting Area: 60 square meter(Install lower than 6M)
- Size: Dia107mm x 54mm
Wired smoke detector
- With photoelectric signal processing technique
- stable operation
- Detecting range: 20M
- Working humidity:≤ 95%RH
- Outpur: NC/NO
- easy installation and flexible output mode for adapting various alarm control panel
- Photoelectric signal processing technique.
- DSP analysis tehcnology
- Excellent performance, low power exhaust and infrared photoelectric diode.
- Unique design, easy installation, manual test function.
Wireless Fire smoke detector
- Operating Voltage: DC9V battery
- Static Current: less than 10uA
- Alarm Current: less than 20mA
- Alarm Indication: Red LED flash
- Sound Level: More than 85dB/m
- Operating Temperature: -10°C ~+50°C
- Operating Humidity: less than 95% RH
- Detecting Area: 20 square meter
- Wireless frequency:433mhz or 315mhz, default 433mhz, please inform us if you need 315mhz
- Timing resistor: 1.5M/3.3M/4.7M optional, default:4.7M
- Radio Distance: 100m(in open area)
- Dimension:107mm dia. * 37mm
Fire Safety
Choose Product:
Flame Detector
UV sensor conventional flame detector
- Fast-respond to ultraviolet radiation emitted by almost all flames
- Artistic and professional housing design
- Wide operating voltage
- 4-wire operation
- Built-in Read More